$ sudo smartctl -a /dev/sda smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.8.11-gentoo+] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Phison Driven SSDs Device Model: KINGSTON SKC310S37A960G Serial Number: 50026B7253094154 Firmware Version: SAFM00.r User Capacity: 960,197,124,096 bytes [960 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Feb 26 19:08:14 2017 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 30) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 2) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 2 Not_In_Use 0x0005 100 100 050 Pre-fail Offline - 0 3 Not_In_Use 0x0007 100 100 050 Pre-fail Always - 0 5 Retired_Block_Count 0x0013 100 100 050 Pre-fail Always - 0 7 Not_In_Use 0x000b 100 100 050 Pre-fail Always - 0 8 Not_In_Use 0x0005 100 100 050 Pre-fail Offline - 0 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 7218 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 587 168 SATA_Phy_Error_Count 0x0012 100 100 000 Old_age Always - 0 170 Bad_Blk_Ct_Erl/Lat 0x0003 100 100 010 Pre-fail Always - 0/3104 173 MaxAvgErase_Ct 0x0012 100 100 000 Old_age Always - 36 (Average 8) 175 Not_In_Use 0x0013 100 100 050 Pre-fail Always - 0 187 Reported_Uncorrect 0x0012 100 100 000 Old_age Always - 0 192 Unsafe_Shutdown_Count 0x0012 100 100 000 Old_age Always - 22 194 Temperature_Celsius 0x0023 072 059 030 Pre-fail Always - 28 (Min/Max 15/41) 196 Not_In_Use 0x0002 100 100 010 Old_age Always - 0 197 Not_In_Use 0x0032 100 100 000 Old_age Always - 0 199 CRC_Error_Count 0x000b 100 100 050 Pre-fail Always - 0 218 CRC_Error_Count 0x000b 100 100 050 Pre-fail Always - 0 231 SSD_Life_Left 0x0013 100 100 000 Pre-fail Always - 100 233 Flash_Writes_GiB 0x000b 100 100 000 Pre-fail Always - 9063 240 Not_In_Use 0x0013 100 100 000 Pre-fail Always - 0 241 Lifetime_Writes_GiB 0x0012 100 100 000 Old_age Always - 6533 242 Lifetime_Reads_GiB 0x0012 100 100 000 Old_age Always - 8299 244 Average_Erase_Count 0x0002 100 100 000 Old_age Always - 8 245 Max_Erase_Count 0x0002 100 100 000 Old_age Always - 36 246 Total_Erase_Count 0x0012 100 100 000 Old_age Always - 2335616 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 7218 - # 2 Short offline Completed without error 00% 52 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.